Fish plant: odor and humidity in office and locker room ducts

In a fish plant the smell of the production hall does not stay in the hall. By mid morning it is already in the manager’s office, with the doors shut and the air conditioning on.

Limpieza de Ductos PanamáBy , consulting engineer in tropical HVACReviewed October 13, 20268 min readShare
Bandejas de madera con pescado vistas desde arriba
Short answer

The offices of a fish plant smell of production because air moves from higher pressure zones to lower pressure ones, and the air conditioning system is usually the path. The usual culprits are a return shared with locker rooms or production corridors, an intake next to an exhaust fan or a branch extended into the hall. The camera locates the opening.

The administration of a fish processing plant knows that scene well. A visitor comes in, the manager receives them in the office, and ten minutes later someone lowers their voice to ask for another fan to be switched on. The hall is forty meters away, with double doors and powerful exhaust fans, and the smell still arrived. Filters are changed, the office is cleaned more carefully, an air freshener is tried, and a week later the smell is back at the same hour.

How does the smell cross from production to the offices?

The EPA building air quality guide for facility managers sums it up in one principle: pressure differences move contaminants from higher pressure zones to lower pressure ones, through any available opening, and the air conditioning system is generally the pathway and the main force of that movement. In a fish plant the hall has large exhaust fans and doors that open often, and the office block is closed up with air conditioning. Depending on how each system is set up, the offices can end up under negative pressure relative to the corridor linking them to production.

There are three frequent paths. The office return sits in a corridor that also serves locker rooms and the production entrance. The outdoor air intake of the office air handler is near the discharge of a hall exhaust fan. Or the office duct was extended at some point to condition a supervision room inside the hall, and that branch brings the air back. It is almost always one of the three, and rarely the one the staff imagine.

When the system allows it, the review of fish processing plants is done by camera through the existing access points, the way the Climatiza technical service performs it.

Why do locker rooms and the canteen make it worse?

Because they are the dampest rooms of the block. Locker rooms receive wet boots, work clothes and showers at every shift change, and the canteen adds kitchen steam. With Panama average humidity at 75.7 % according to ETESA and IMHPA, those rooms do not dry by themselves, and the duct serving them absorbs odor and moisture in equal parts. If that duct shares an air handler with the offices, the path is already made.

A review of airborne contamination in the food industry (Masotti et al., 2019) notes that air is a vehicle of cross contamination in plants and that loads vary from one plant to another and from one day to the next within the same plant. In plain words, the smell and moisture that rise today do not have to be those of last week, which is why a single visit rarely suffices to understand the whole pattern.

Why does it matter if it is only a smell?

Because a persistent smell in the offices says something about the separation between areas, and that separation is what a food plant tries to show. It matters for the daily work of the administrative staff, who spend eight hours breathing whatever the hall lets through, and for the visit of the buyer or the auditor who walks into the office and takes away a first impression. And it matters for the equipment: an office duct impregnated with moisture and residue holds the odor and gives it back every time the air is switched on.

It is worth stating clearly what is not claimed. Duct cleaning has not been shown to prevent health problems according to the EPA and the CDC, and the report says nothing about the product or about people. It describes the condition of the duct and the air separation between blocks, which is what the plant can show.

What does a visit to a plant look like, step by step?

The visit starts with a conversation with the maintenance head: at what hour the smell is strongest, which rooms complain first, which exhaust fans come on in which shift. Then, with the hall in operation, a simple test is done at the doors between blocks with a strip of paper or a light ribbon: if it is pulled toward the office, the pressure is inverted. That test takes minutes and gives more direction than many hours of cleaning.

The camera goes in afterward, during a plant shutdown, with the air handlers off. A camera inspection runs through the office and locker room duct from the grille to the air handler and marks where the branch or opening bringing the smell appears. What turns up most is an added branch without its own return, a damper that does not close, damp dust with a film that retains the odor and an air handler filter that smells of production when removed. Without that tour the cleaning is blind and the smell returns within a week.

An illustrative case, not a real client: a plant with offices adjoining the hall through a corridor with locker rooms. The camera shows that the office return takes air from the corridor, and that the locker room duct connects to the same return. The solution is not cleaning but separating: give the offices their own return, close the shared branch and restore the automatic door closer. Afterward the duct with residue is cleaned and the filter is changed.

Which mistakes come up most, and when is it worth checking?

The first is attacking the smell with scented products instead of looking for the opening. The second is cleaning the office duct without checking the pressure between blocks. The third is changing the office filters in the high season and not at the end of it: a filter loaded during the season is a reservoir of odor. The load follows production, so in the months with the heaviest landings the exhaust fans run more hours and the pressure difference with the offices grows. It is better for the duct check to fall in the low season or the closed season, with the hall stopped, and for the pressure verification to be done in the middle of operations, which is when the problem is felt.

  • Paper or ribbon test at the doors between blocks, with the hall in operation.
  • Camera tour of the office and locker room duct, with the plant stopped.
  • Location of the outdoor air intake relative to the exhaust fan discharges.
  • Odor log kept by the administrative staff: date, time and room, to cross with the shift.
  • Report with date, areas, what was checked, what was cleaned, photos and pending items, to keep with the maintenance records.

Sanitary inspections of food plants focus on the process area, but they usually look at the building maintenance records and ask about the separation between areas, and a report like this is filed with them. The same criterion works in other plants with damp areas and offices and in warehouses with an office inside the hall, where the air path changes but the logic is the same. When each section is due for cleaning is decided with the criteria of the cleaning guide, and the other kinds of place show how the calendar varies.

Questions about a specific building can be sent to Climatiza, and the service description shows what a visit includes.

Sources

On this site

Why does inspecting and cleaning ducts matter?

These are the technical reasons, with their source, why the condition of the ducts is checked before deciding. Duct cleaning has not been shown to prevent health problems according to the EPA and the CDC, and it is proposed only when the observed condition justifies it.

AdvantageData with sourceWhat it means in practice
Know whether cleaning is needed before decidingThe EPA states in its duct cleaning guide that cleaning is justified for visible mold, pests or a notable buildup of dust and debris.A camera inspection documents the condition and allows a decision based on evidence, without unnecessary work.
Anticipate the tropical humidityAccording to ETESA (Tocumen station, 1977 to 2010), mean annual relative humidity in Panama is 75.7 % and rises to between 78.2 and 82.4 % in the rainy months.The condensate pan, the drain and the coil are checked first, because that is where moisture builds up.
Keep humidity under controlThe EPA recommends in its guide to mold and moisture keeping indoor relative humidity below 60 % and drain pans clean and draining freely.A humidity reading and a clean pan limit the conditions in which mold grows.
A local figure that changes the decisionAccording to INEC, in 2024 Colón Free Zone imports totaled B/.12,646.5 million, 35.9% below 2023, and re-exports B/.12,208.2 million, 8.6% below. 74.6% of imported value arrived by sea. The figures give the scale of the goods that pass through warehouses and sheds. (INEC, Foreign Trade Yearbook, Colón Free Zone 2024).It is the sector context taken into account when planning the visit.

Frequently asked questions

Because air goes from higher pressure zones to lower pressure ones and the air conditioning is usually the path. The usual causes are a return shared with corridors or locker rooms, an intake next to an exhaust fan or a branch extended into the hall.

Only if the smell stays in the duct residue. If there is an opening bringing hall air, the smell returns within days. First the opening is located with the camera and the separation is corrected, and then whatever has a film is cleaned.

It is worth doing in the low season or the closed season, with the hall stopped, and verifying the pressure between blocks in the middle of operations. Filters are changed at the end of the high season. The date depends on what the camera shows.

Pressure differences. The EPA guide for building managers states that contaminants move from the higher-pressure zone to the lower-pressure one through any opening, and that the air conditioning is generally the main pathway. If the offices end up under negative pressure relative to the corridor, the odor comes in.

Which rooms the main return draws air from and whether any connects to the production floor, the location of the outdoor intake relative to exhaust fan discharges, branches serving rooms inside the plant, and the condition of the doors between blocks. Then the inside of the duct is viewed with a camera.

Written by Ramiro Oscar LunaConsulting engineer and tropical HVAC specialist, collaborator and technical analyst at Climatiza.

Keep reading the guide

Related toolDuct inspection plannerEstimate the level of attention your system needs based on use and warning signs.Open planner →
Técnico de aire acondicionado con mascarilla revisando una unidad exterior

Request an inspection

Do you want to know the condition of your system?

A camera inspection lets you see the inside of the ducts before deciding what to do. Message us and we will confirm availability.